Load Cell 20Kg
Br1,050.00
Load Cell (20kg):
- Capacity: 20kg (maximum weight it can measure).
- Output Sensitivity: Typically around 2.0 ± 0.1 mV/V. This means for every volt of excitation voltage applied to the load cell, it will output 2.0 millivolts of signal per kilogram of weight.
- Non-linearity: ±0.03% of full scale (maximum deviation from a linear relationship between weight and output).
- Hysteresis: ±0.02% of full scale (difference in output when increasing or decreasing the weight).
- Repeatability: ±0.01% of full scale (how consistently it produces the same output for the same weight).
- Creep: ±0.03% of full scale (change in output over time under a constant load).
- Zero Balance: ±1% of full scale (output with no load applied).
- Input Resistance: 405 ± 10 ohms.
- Output Resistance: 350 ± 3 ohms.
- Excitation Voltage: 5V to 10V DC (recommended), up to 15V DC (maximum).
- Dimensions: Varies by model, but often around 34mm x 34mm x 8mm.
- Material: Aluminum alloy or stainless steel.
HX711 Amplifier:
- A/D Converter: 24-bit ADC, which means it can resolve very small changes in the load cell’s output signal, resulting in higher accuracy.
- Operating Voltage: 2.6V to 5.5V.
- Current Consumption: Typically less than 1.7mA during operation and less than 1μA in shutdown mode.
- Interface: Serial (2-wire: data and clock).
- Output Data Rate: 10Hz or 80Hz (selectable).
- PCB Dimensions: Typically around 34.2 x 20 x 3 mm.